Technical Specifications of DZL Series Coal Fried Steam Boiler

Parameter/Data/Type
★DZL1-0.7-A II
DZL1-1-A II
★DZL2-1-A II
DZL2-1.25-A II
★DZL4-1.25-A II
DZL4-1.57-A II
Rated evaporation capacity
t/h
1
2
4
Rated working pressure
Mpa
0.7
1
1.25
Rated Steam temperature
170
183
194
Water-supply temperature
20
20
20
Boiler heating area
Boiler
m2
32.4
59
114.4
Economizer
m2
12.51
16.7
38.5
Effective area of grate
m2
2.05
3.17
4.94
Fuel available
Coal type(Designed)
Bituminous class II
Bituminous class II
Bituminous class II
Low heating value
kj/kg
18757
18757
18757
Fuel consumption
kg/h
170
335
656
Thermal efficiency
%
76.8
78.7
77.9
Dimension of maximal part in transportation(L×W×H)
m
5.2×2×2.9
5.7×2.6×3.38
6.6×2.65×3.55
Weight of maximal part in transportation
t
12.3
20
26.7
Overall dimension of boiler after assembled(L×W×H)
m
5.3×3.9×4.2
6×3.85×5
7.22×4.04×4.9
Auxiliary Machines
Name
Type&Parameter
Type&Parameter
Type&Parameter
Induced Draft Fan
GY1-18 4#Right0°
H=2544Pa
Q=4400m3/h
GY2-18 4#Right0°
H=3340Pa
Q=7000m3/h
GY4-18 3#Right0°
H=3960Pa
Q=13000m3/h
ElectromotorY132S-4B3
N=5.5kw
ElectromotorY160M-4B3
N=11kw
ElectromotorY180L-4B3
N=22kw
Forced Draft Fan
4-72-3.2ARight315°
H=792-1300Pa
Q=1688-3517m3/h
GG2-11No.6.3A
H=1450Pa
Q=3100Nm3/h
T4-72-4.5A Right315°
H=2539Pa
Q=5780-10010m3/h
ElectromotorY90L-2
N=2.2kw
ElectromotorY100L-2-4
N=3kw
ElectromotorY132S2-2
N=7.5kw
Electric pump
W2.4-10.5
H=105m
Q=2.4m3/h
DG6-25×5
H=125m
Q=6.3m3/h
DG6-25×7
H=175m
Q=6.3m3/h
ElectromotorY100L-2
N=3kw
ElectromotorY132S1-2
N=5.5kw
ElectromotorY132S2-2B3
N=7.5kw
Governor
GL-5P/II
Stepless speed governor
GL-5P/II
Stepless speed governor
GL-5P/II
Stepless speed governor
ElectromotorYCT112-4A
N=0.55kw
ElectromotorYCT112-4A
N=0.55kw
ElectromotorYCT112-4A
N=0.55kw
Ash Extractor
Screw type
Screw type
Screw type
ElectromotorY90S-6
N=0.75kw
ElectromotorY90S-6
N=1.1kw
ElectromotorY90L-6
N=1.1kw
Dust Collector
Multi-tube XTD-1
Multi-tube XTD-2
Multi-tube XTD-4
Technical Specifications of DZL Series Coal Fried Hot Water Boiler
Parameter/Data/Type
★DZL0.7-0.7/95/70-A II
★DZL1.4-0.7/95/70-A II
★DZL2.8-0.7/95/70-A II
Rated heat capacity
MW
0.7
1.4
2.8
Rated working pressure
Mpa
0.7
0.7
0.7
Rated output water temperature
95
95
95
Rated back-water temperature
70
70
70
Boiler heating area
Boiler
m2
32.4
59
114.6
Effective area of grate
m2
2.05
3.17
4.94
Fuel available
Coal type(Designed)
Bituminous class II
Bituminous class II
Bituminous class II
Low heating value
kj/kg
18757
18757
18757
Fuel consumption
kg/h
170
335
656
Thermal efficiency
%
76.8
78.7
77.9
Dimension of maximal part in transportation(L×W×H)
m
5.25×2.05×2.9
5.7×2.6×3.4
6.3×2.65×3.55
Weight of maximal part in transportation
t
13
21
23
Overall dimension of boiler after assembled(L×W×H)
m
5.3×3.9×4.2
6×3.85×5
7×4×5
Auxiliary Machines
Name
Type&Parameter
Type&Parameter
Type&Parameter
Induced Draft Fan
GY1-18 4#Right0°
H=2544Pa
Q=4530m3/h
GY2-18 4#Right0°
H=3340Pa
Q=7000m3/h
GY4-184#Right0°
H=3724Pa
Q=13000m3/h
ElectromotorY132S-4B3
N=5.5kw
ElectromotorY160M-4B3
N=11kw
ElectromotorY180L-4B3
N=22kw
Forced Draft Fan
4-72-3.2ARight315°
H=637-1020Pa
Q=1630-3600m3/h
GG2-11No.6.3A右225。
H=921Pa
Q=3700Nm3/h
T4-72-4.5A Right315°
H=2539~1618Pa
Q=5780-10010m3/h
ElectromotorY90L-2
N=2.2kw
ElectromotorY100L-4
N=3kw
ElectromotorY132S1-2
N=7.5kw
Makup pump
1W2.4-10.5
H=105m
Q=2.4m3/h
JGGC2-90/10
H=90m
Q=2m3/h
JGGC-88/11
H=88m
Q=4m3/h
ElectromotorY100L-2
N=3kw
ElectromotorY90S-2
N=1.5kw
ElectromotorY90L-2
N=2.2kw
Governor
GL-5P/II
Stepless speed governor
GL-5P/II
Stepless speed governor
GL-5P/II
Stepless speed governor
ElectromotorYCT112-4A
N=0.55kw
ElectromotorYCT112-4A
N=0.55kw
ElectromotorYCT112-4A
N=0.55kw
Ash Extractor
Screw type
Screw type
Screw type
ElectromotorY90S-6
N=0.75kw
ElectromotorY90L-6
N=1.1kw
ElectromotorY90L-6
N=1.1kw
Dust Collector
Multi-tube XTD-1
Multi-tube XTD-2
Multi-tube XTD-4
Note:The data in tables are only specific for marked boiler